Autoclave Horizontal High Pressure Labappara
Autoclave Horizontal High Pressure Labappara

Autoclave Horizontal High Pressure Labappara

Autoclave Horizontal High Pressure Labappara Specification

  • Type
  • Horizontal, High Pressure Steam Autoclave
  • Chamber Size
  • 1000 x 500 mm (Dia x Depth)
  • Chamber Thickness
  • 8 mm (SS 304 grade)
  • Outer Size
  • 1800 x 800 x 1500 mm (Approx.)
  • Compressed Air
  • 6-8 Bar (approx), Required for operation
  • Door Type
  • Horizontal sliding, Radial Locking Mechanism
  • Design Pressure
  • 2.5 Bar
  • Working Pressure
  • 2.0 Bar
  • Design Temperature
  • up to 139C
  • Heat Uniform
  • Uniform heat distribution 1C
  • Insulation
  • 2 layers, Glass Wool
  • Net Weight
  • Approx. 500 kg
  • Recording Parameters
  • Digital recorder for temperature and pressure
  • Spraying Mode
  • Rotary spray, Multi-directional
  • Outer Trolley
  • Removable, Stainless Steel
  • Inner Trolley
  • Removable, Perforated Stainless Steel
  • Spraying Piping
  • 304 grade Stainless Steel Nozzle Piping
  • Steam
  • Required, External Steam Generator Compatible
  • Sterilizing Temperature
  • 121C - 134C
  • Working Temperature
  • Up to 134C
  • Sterilization Time
  • 099 minutes adjustable
  • Temperature Scope
  • Ambient to 134C
  • Piping System
  • Stainless Steel 304 Seamless Pipes
  • Valves
  • Sterile, Safety, Vacuum Breaker, Control
  • Power Consumption
  • 9.5 kW approx. (with electric heater type)
 

Autoclave Horizontal High Pressure Labappara Trade Information

  • FOB Port
  • Delhi
  • Payment Terms
  • Paypal, Letter of Credit (L/C), Telegraphic Transfer (T/T)
  • Supply Ability
  • 20 Per Week
  • Delivery Time
  • 8 Days
  • Sample Available
  • Yes
  • Sample Policy
  • If order is confirmed we will reimburse the sample cost
  • Main Export Market(s)
  • Western Europe, Australia, North America, Eastern Europe, Middle East, Africa, Central America, South America, Asia
  • Main Domestic Market
  • All India
  • Certifications
  • ISO, CE, FDA, WHO-GMP
 

About Autoclave Horizontal High Pressure Labappara

Horizontal Autoclave High Pressure Cylindrical Standard is made of complete Stainless Steel

Horizontal Autoclave High Pressure Cylindrical Standard is electrically heated sterilizer under saturated steam of Adjustable pressure of 10 to 20 psi.

Triple Wall construction with boiler & steam jacket is made of thick stainless steel and gap is filled with high grade glass wool to bring the temperature to a minimal level.

The lid has thick Stainless Steel Radial Locking System and can be sealed by a jointless neoprene rubber gasket.

Horizontal Autoclave is fitted with automatic pressure control switch and automatic low water level cut off device.

Draincock has also provided.

It works on 440 Volts



Superior Build Quality

Crafted with both inner and outer chambers made of heavy gauge stainless steel 304, the autoclave offers excellent durability and corrosion resistance. With seamless piping and a silicone gasket, operational reliability is further enhanced, making it suitable for demanding environments.


Advanced Control & Safety

The system utilizes a digital microprocessor PID controller, automatic pressure release, and multiple safety cut-offs, ensuring user safety and process accuracy. The LCD display and dual pressure gauges provide real-time data monitoring for seamless operation.


Efficient Sterilization Process

Uniform heat distribution, multi-directional rotary spray, and adjustable temperature and sterilization time parameters facilitate efficient and customizable sterilization cycles. The autoclave supports ambient to 134C, accommodating a wide variety of sterilization requirements.

FAQs of Autoclave Horizontal High Pressure Labappara:


Q: How does the horizontal high-pressure autoclave achieve uniform heat distribution during sterilization?

A: The autoclave features a multi-directional rotary spray mode and advanced PID-controlled heating. Paired with seamless stainless steel nozzle piping and glass wool insulation, it ensures uniform heat distribution with a deviation of 1C throughout the chamber.

Q: What safety features are integrated into this autoclave to protect users and samples?

A: Safety mechanisms include automatic pressure release, low water and over-temperature cut-offs, a sterile safety valve, vacuum breaker, and a silicone high temperature-resistant gasket. These features collectively prevent accidental exposure and increase operational reliability.

Q: When should the removable stainless steel trolleys be used during the sterilization process?

A: Both the inner and outer removable trolleys are designed for safe and efficient loading and unloading. Use them before initiating the sterilization cycle to arrange samples and following completion to easily transfer sterilized materials for further handling.

Q: Where can the Autoclave Horizontal High Pressure Labappara be installed?

A: Its compact yet robust design (1800 x 800 x 1500 mm, approx.) is suitable for laboratories, pharmaceutical industries, and medical facilities. Installation requires access to a 220/230V AC power supply, compressed air (68 Bar), and an available steam source.

Q: What is the process for adjusting sterilization temperature and time?

A: Temperature can be adjusted from ambient to 134C, and sterilization time from 0 to 99 minutes, using its digital microprocessor PID controller. The LCD display allows users to set, monitor, and record temperature and pressure parameters throughout the process.

Q: How does using this autoclave benefit laboratory operations?

A: The unit provides reliable sterilization cycles with precise control, enhanced safety, and thorough documentation. These capabilities promote increased efficiency, reduced contamination risks, and ensure compliance with laboratory or industrial standards for sterilization.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Autoclave Category

Autoclave Pressure Cooker

Autoclave Pressure Cooker

Valves : Automatic Control Valves

Chamber Thickness : 4 mm

Working Temperature : 121C

Steam : Saturated Steam (from External Generator)

Recording Parameters : Digital Chart Recorder

Net Weight : 260 Kg

ConXport Table Top Autoclave Without Vacuum

ConXport Table Top Autoclave Without Vacuum

Valves : Safety Valve, Pressure Gauge, Steam Release Valve

Chamber Thickness : 35 mm (Stainless Steel)

Working Temperature : 121C

Steam : External or InBuilt Steam Generator

Recording Parameters : Manual Recording

Net Weight : Approx. 45 kg

Vertical Autoclave

Vertical Autoclave

Valves : Pressure relief valve included

Chamber Thickness : 4mm

Working Temperature : 121C

Steam : Required

Recording Parameters : Not included

Net Weight : Approx. 45 kg