Vertical Autoclave Double Wall
Vertical Autoclave Double Wall

Vertical Autoclave Double Wall

Vertical Autoclave Double Wall Specification

  • Type
  • Vertical Double Wall (laboratory type)
  • Chamber Size
  • 420mm x 400mm
  • Chamber Thickness
  • 6 mm
  • Outer Size
  • 550mm x 750mm
  • Compressed Air
  • 6-8 bar (for door and seal operation)
  • Door Type
  • Radial Locking, Manual/Automatic
  • Design Pressure
  • 2.5 bar
  • Working Pressure
  • 2 bar
  • Design Temperature
  • 140C
  • Heat Uniform
  • 1C
  • Insulation
  • High density glass wool or ceramic
  • Net Weight
  • 320 kg
  • Recording Parameters
  • Digital chart recorder, PLC data log
  • Spraying Mode
  • Uniform multi-directional spray
  • Outer Trolley
  • Stainless Steel with guide wheels
  • Inner Trolley
  • Removable perforated Stainless Steel
  • Spraying Piping
  • 316L Stainless Steel, high pressure
  • Steam
  • Saturated steam, external or built-in generator
  • Sterilizing Temperature
  • 121C to 134C
  • Working Temperature
  • Up to 134C
  • Sterilization Time
  • 15-60 minutes (programmable)
  • Temperature Scope
  • Ambient to 134C
  • Piping System
  • CIP integrated piping, safety systems
  • Valves
  • Stainless Steel safety and exhaust valves
  • Power Consumption
  • 7.5 KW
  • Sealing Type
  • Silicon rubber gasket (heat resistant) sealed
  • Display
  • Digital LCD display for program control
  • Material of Construction
  • Inner & Outer chamber made of 304/316 Stainless Steel
  • Standards
  • Complies with ISO/CE standards
  • Control System
  • Microprocessor/PLC based automatic control
  • Voltage
  • 220/380V, 50/60Hz
  • Accessories
  • Baskets, trays, validation ports
  • Door Sealing
  • Pneumatic/Manual options
  • Safety Features
  • Over-pressure protection, temperature cut-off
  • Finish
  • Polished or matt as required
  • Drain System
  • Automatic condensate drain
 

Vertical Autoclave Double Wall Trade Information

  • FOB Port
  • Delhi
  • Payment Terms
  • Letter of Credit (L/C), Paypal, Telegraphic Transfer (T/T)
  • Supply Ability
  • 15 Per Week
  • Delivery Time
  • 7 Days
  • Sample Available
  • Yes
  • Sample Policy
  • If order is confirmed we will reimburse the sample cost
  • Main Export Market(s)
  • Asia, Australia, South America, Western Europe, Middle East, Central America, Eastern Europe, North America, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO, CE, FDA, WHO-GMP
 

About Vertical Autoclave Double Wall

Vertical Autoclave Double Wall is made of Inner Stainless Steel and outer Mild Steel pre treated Epoxy Powder Coated

Vertical Autoclave Double Wall is electrically heated sterilizer under saturated steam of Adjustable pressure of 10 to 20 psi. 

Double Wall construction with boiler & steam jacket is made of thick stainless steel and gap is filled with high grade glass wool to bring the temperature to a minimal level.

The outer chamber is made out of thick mild steel.

The lid is made of thick gunmetal plate and can be sealed by a jointless neoprene rubber gasket by wing nuts through hinged bolts by engaging slotted lugs on rim of the cover. 

Vertical Autoclave is fitted with dial pressure gauge, air/ steam release cock, spring loaded safety valve adjustable to any required point from 10 psi to 20 psi with accuracy + 3 psi. 

Draincock has also provided. 

Adouble safety valve has also been provided along with inlet. 

Optional Features on Extra Cost :

i)Automatic low-water level cut off- device.

ii)pressure Control switch.

iii)Water lever arrangement.

iv)Dressing bins for various size. 

v)Radial lock.

vi)Digital temp. indicator

 



Advanced Control & Safety

The Vertical Autoclave is designed with a microprocessor or PLC-based control system, providing automatic program management of sterilization cycles. Enhanced safety is ensured with over-pressure protection mechanisms, temperature cut-off, and stainless-steel valves. The digital LCD display allows users to monitor process parameters, making it easy to operate and maintain high standards of reliability and safety.


Optimized Sterilization Performance

Engineered to work efficiently at temperatures from 121C up to 134C, the units chamber features a double wall construction crafted from 304/316 stainless steel, complemented by uniform multi-directional spray, programmable sterilization times, and 1C heat uniformity. Integrated insulation minimizes heat loss, while automatic condensate drainage streamlines operations and improves effectiveness.


Adaptable to Diverse Environments

This autoclave is suitable for laboratories, hospitals, and research institutes. With options for manual or pneumatic door sealing, stainless steel outer trolley with guide wheels, and removable inner trolleys, it meets varied requirements for user convenience and operational versatility. Compliance with ISO and CE standards ensures it is ideal for export and institutional use.

FAQs of Vertical Autoclave Double Wall:


Q: How does the vertical autoclave ensure effective sterilization of materials?

A: The autoclave achieves effective sterilization through programmable control of temperatures (121C134C), uniform multi-directional steam spraying, accuracy within 1C, and programmable sterilization times from 15 to 60 minutes, ensuring reliable decontamination of instruments and materials.

Q: What safety mechanisms are included in the autoclave?

A: Safety is prioritized through over-pressure protection, temperature cut-off, stainless steel safety and exhaust valves, a silicon rubber heat-resistant gasket for tight sealing, and both automatic and manual door locking mechanisms to minimize operational risks.

Q: When should the automatic and manual door options be used?

A: The pneumatic (automatic) door option is ideal for high-throughput settings where efficiency is crucial, while the manual door option provides flexibility and control, particularly useful in smaller labs or as a backup measure during maintenance of the pneumatic system.

Q: Where can this vertical autoclave be installed or utilized?

A: It is well-suited for laboratories, hospitals, and research facilities requiring reliable sterilization. The compact outer size (550mm x 750mm) and mobile stainless steel trolley design allow flexible installation and convenient operation in various institutional environments.

Q: What is the process for cleaning or maintaining the autoclave?

A: Maintenance is streamlined by the integrated CIP (Clean-In-Place) piping system, automatic condensate drain system, removable stainless steel trolleys, and polished or matt finishes that facilitate cleaning, ensuring hygiene and prolonging equipment life.

Q: How are program parameters and cycles monitored and recorded?

A: All sterilization parameters and cycles are managed via a digital LCD display and can be logged automatically with the PLC data log and digital chart recorder for record-keeping, process validation, and regulatory compliance.

Q: What are the key benefits of using this laboratory autoclave?

A: Key benefits include fast and reliable sterilization, robust safety, high performance through advanced automation, compliance with ISO/CE standards, versatile loading/unloading, energy-efficient design, and corrosion-resistant stainless steel construction for long-term durability.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Autoclave Category

Vertical Stainless Steel Portable Autoclave

Vertical Stainless Steel Portable Autoclave

Temperature Scope : Room temperature to 134C

Outer Size : 520 x 640 mm

Outer Trolley : Stainless steel, removable

Door Type : Radial locking system

Recording Parameters : Temperature, Pressure digital display

Type : Other, Vertical portable autoclave

Automatic Horizontal Steam Sterilizer

Automatic Horizontal Steam Sterilizer

Temperature Scope : Up to 134C

Outer Size : 1460 x 690 x 900 mm

Outer Trolley : Stainless Steel, Heavy Duty

Door Type : Automatic horizontal sliding door

Recording Parameters : Digital chart recorder

Type : Other, Automatic Horizontal Steam Sterilizer

ConXport Vertical Autoclave Double Wall Fully Automatic Made of Stainless Steel

ConXport Vertical Autoclave Double Wall Fully Automatic Made of Stainless Steel

Temperature Scope : Ambient to 134C

Outer Size : Custom sizes available depending on model (standard models from 400 x 400 mm upwards)

Outer Trolley : Stainless Steel Removable Support Trolley (Optional)

Door Type : Radial Locking Single Door (Manual or Motorized)

Recording Parameters : Digital printout of temperature, pressure, and sterilization time cycle

Type : Other, Vertical doublewall, fully automatic

Fully Automatic Horizontal Steam Autoclave

Fully Automatic Horizontal Steam Autoclave

Temperature Scope : 105C 138C

Outer Size : 2000 mm x 700 mm x 900 mm

Outer Trolley : SS304, heavy duty construction

Door Type : automatic sliding door

Recording Parameters : Digital printout for time, temperature, pressure

Type : Other, Fully automatic, horizontal



Back to top