08045815886
Change Language
ConXport  Atomic absorption spectrophotometer
ConXport  Atomic absorption spectrophotometer

ConXport Atomic absorption spectrophotometer

ConXport Atomic absorption spectrophotometer Specification

  • Power Supply
  • AC Mains
  • Display Type
  • Digital graphical LCD display
  • Heating Capacity
  • Suitable for atomization via air-acetylene or nitrous oxide-acetylene flame
  • Shape
  • Rectangular console
  • Glass Type
  • Borosilicate (in sample tube and burner components)
  • Accuracy
  • 0.5% for absorbance readings
  • Control Type
  • Microprocessor controlled
  • Temperature Resistance
  • Up to 1000C (Burner system)
  • Features
  • Automatic wavelength selection, auto gas control, built-in safety systems, data storage, USB connectivity
  • Speed Range
  • Up to 2.4 L/min (nebulizer flow)
  • Type
  • Atomic Absorption Spectrophotometer
  • Dimension (L*W*H)
  • Approx. 590 x 520 x 450 mm
  • Equipment Type
  • Analytical Laboratory Instrument
  • Equipment Materials
  • Stainless Steel, premium grade alloys and flame-resistant plastics
  • Power
  • 1200 W
  • Voltage
  • 230 V AC, 50/60 Hz
  • Material
  • Corrosion-resistant metal construction
  • Application
  • Quantitative chemical analysis of metals in samples
  • Wavelength Range
  • 190 - 900 nm
  • Flame Type
  • Air-Acetylene or Nitrous Oxide-Acetylene
  • Nebulizer Type
  • High-efficiency pneumatic/nebulizer
  • Spectral Bandwidth
  • 0.2, 0.4, 1.0, 2.0 nm (selectable)
  • Detector Type
  • Photomultiplier Tube
  • Burner Head
  • Titanium or stainless steel, 100 mm slot
  • Readout Units
  • Absorbance, concentration, emission, percent transmission
  • Data Output
  • USB port, RS232 communication
  • Safety Interlocks
  • Flame sensor, gas pressure sensor, overload protections
  • Lamp Positions
  • 4 (automatic turret or manual switch)
  • Aspiration Rate
  • 2 - 5 mL/min
 

ConXport Atomic absorption spectrophotometer Trade Information

  • FOB Port
  • Delhi
  • Payment Terms
  • Letter of Credit (L/C), Paypal, Telegraphic Transfer (T/T)
  • Supply Ability
  • 15 Per Week
  • Delivery Time
  • 6-7 Days
  • Sample Available
  • Yes
  • Sample Policy
  • If order is confirmed we will reimburse the sample cost
  • Main Export Market(s)
  • Asia, Australia, South America, Africa, Central America, Eastern Europe, North America
  • Main Domestic Market
  • All India
  • Certifications
  • ISO,CE,FDA,WHO-GMP
 

About ConXport Atomic absorption spectrophotometer

Product Description Instrument Type - Single Beam ReflectionAchromatic Optics System
Monochromatic- Aberration Corrected Czerny-Turner
Dispersionelements - Grating system 1200 line/mm characterization area 40mm2Scintillation wavelength 250nm
Bandwidth -0.1,0.2,0.4,1nm(4 step auto switching)
WL Range -190-900 NM
WL Accuracy- 0.2NM
WLRepeatability - 0.1 nm max
Resolution- Min 3 lines (279.5 & 279.8 peak and Valley )
HCL housing- Standard 4 lamp turret .( 1 for measurement , 3 in warm-up mode )Option :- 6Lamp / 8 Lamp Turret
Gas control- Automatic control & optimization (flow/pressure)
Safetymeasures - Gas Leak check, prevention of gas release when flame dies out,prevention of flashback through pressure monitoring.
Measurement- Aberration-corrected Czerny-Turner mounting
PhotometricRange - 0-125%, -0.1-3.00A
StaticBaseline Drift - (Cu) +-0.003A/30min
DynamicBaseline Drift t - (Cu) +-0.006A/30min
BackgroundCorrection - High speed self-reversal (BGC-SR) method: High-speed D2 lampmethod (BGC-D2)
CharacteristicConcentration - (Cu) 0.025 g/ml max
Detectionlimit - (Cu) 0.004 g/ml max
Precision -RDS =0.5%
Burner -Air cooled Titanium
Nebulizer -High-efficient Nebulizer
Spraychamber - Anticorrosion material
Safetymeasures - Flame fuel gas, power assisted gas abnormal pressure protection
Test Manner- Flame , flame emission
Concentration- standard curve, standard addition, interpolation
Times ofrepetitive - Measurement 1-30 times, Average Value of A&C Report Printparameters, date result
Dimension& Weight(Flame)700420550 mm; 103 kg(approx.)
Power (Mainunit - with(Flame) - AC 220 V 10%, 50 Hz without sharp fluctuations.
WorkingTemperature range 10-300C
WorkingHumidity range - 40%-85%

 



Precision and Flexibility in Metal Analysis

ConXports Atomic Absorption Spectrophotometer delivers reliable quantitative results through microprocessor-controlled calibration. The adjustable spectral bandwidths and selectable burner heads allow for tailored analysis, accommodating varying sample requirements and atomization conditions. Its intuitive digital display streamlines operation, making complex data accessible and efficiently managed.


Robust Safety and Durability Features

Engineered with built-in safety interlocks including flame and gas pressure sensors, this equipment prioritizes laboratory safety. The titanium/stainless steel burner head and corrosion-resistant metal frame ensure long service life, even at sustained high temperatures. Both automation and manual operation options increase versatility for diverse laboratory environments.

FAQs of ConXport Atomic absorption spectrophotometer:


Q: How does the ConXport Atomic Absorption Spectrophotometer ensure precise metal quantification?

A: The device utilizes microprocessor-controlled calibration, automatic wavelength selection, and adjustable spectral bandwidths, which together provide accurate and repeatable absorbance readings with an error margin of 0.5%.

Q: What safety features are included to protect users during operation?

A: Safety interlocks such as flame sensors, gas pressure monitors, and overload protections are integrated to automatically halt operation in hazardous conditions, ensuring user and equipment protection.

Q: When is this spectrophotometer typically used in laboratories?

A: It is commonly employed during routine quantitative chemical analysis, especially for detecting and measuring metal ions in environmental, industrial, and clinical samples.

Q: Where can the ConXport Atomic Absorption Spectrophotometer be installed?

A: This spectrophotometer can be installed in analytical laboratories, research centers, industrial facilities, and universities where metal quantification is essential.

Q: What is the process for using the spectrophotometer for sample analysis?

A: Users prepare the sample, select appropriate wavelength and flame settings, and introduce the sample via the high-efficiency nebulizer. The device then measures absorbance, emission, or concentration, displaying results on its digital LCD screen.

Q: What are the main benefits of its corrosion-resistant metal construction and borosilicate components?

A: Corrosion-resistant metals and borosilicate glass provide durability, minimize contamination, and allow operation at temperatures up to 1000C, enhancing instrument longevity and measurement reliability.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Spectrophotometer Category

ConXport FTIR SPECTROPHOTOMETER

ConXport FTIR SPECTROPHOTOMETER

Control Type : Microprocessorbased control

Accuracy : 0.01 cm

Material : ABS Plastic, Aluminum Alloy

Voltage : 220 V AC

Shape : Rectangular

Features : High resolution, wide spectral range, userfriendly interface, USB connectivity

ConXport  3.  UV-VIS Spectrophotometer Double Beam

ConXport 3. UV-VIS Spectrophotometer Double Beam

Control Type : MicroprocessorControlled

Accuracy : 0.5 nm (Wavelength)

Material : Stainless Steel, Glass, Highquality Plastic

Voltage : 220 V AC

Shape : Rectangular

Features : Double beam optics, Wide wavelength range, Builtin printer, Data storage

ConXport Single-Beam spectrophotometer

ConXport Single-Beam spectrophotometer

Control Type : Keypad control

Accuracy : 0.5%T

Material : ABS and metal components

Voltage : 220V / 50Hz

Shape : Rectangular

Features : High accuracy, stable performance, easy operation, automatic zero adjustment, safety protection, data output port

ConXport Micro UV VIS Spectrophotometer

ConXport Micro UV VIS Spectrophotometer

Control Type : Touch Control Panel

Accuracy : 1 nm

Material : ABS, Metal

Voltage : 220 V / 50 Hz

Shape : Rectangular

Features : Requires small sample volume, high accuracy, fast measurement, USB data output



Back to top