08045815886
Change Language
ConXport  Atomic absorption spectrophotometer
ConXport  Atomic absorption spectrophotometer

ConXport Atomic absorption spectrophotometer

ConXport Atomic absorption spectrophotometer Specification

  • Temperature Resistance
  • Up to 1000°C (Burner system)
  • Display Type
  • Digital graphical LCD display
  • Features
  • Automatic wavelength selection, auto gas control, built-in safety systems, data storage, USB connectivity
  • Glass Type
  • Borosilicate (in sample tube and burner components)
  • Shape
  • Rectangular console
  • Speed Range
  • Up to 2.4 L/min (nebulizer flow)
  • Control Type
  • Microprocessor controlled
  • Heating Capacity
  • Suitable for atomization via air-acetylene or nitrous oxide-acetylene flame
  • Accuracy
  • ±0.5% for absorbance readings
  • Power Supply
  • AC Mains
  • Type
  • Atomic Absorption Spectrophotometer
  • Dimension (L*W*H)
  • Approx. 590 x 520 x 450 mm
  • Equipment Type
  • Analytical Laboratory Instrument
  • Equipment Materials
  • Stainless Steel, premium grade alloys and flame-resistant plastics
  • Power
  • 1200 W
  • Voltage
  • 230 V AC, 50/60 Hz
  • Material
  • Corrosion-resistant metal construction
  • Application
  • Quantitative chemical analysis of metals in samples
  • Spectral Bandwidth
  • 0.2, 0.4, 1.0, 2.0 nm (selectable)
  • Flame Type
  • Air-Acetylene or Nitrous Oxide-Acetylene
  • Detector Type
  • Photomultiplier Tube
  • Burner Head
  • Titanium or stainless steel, 100 mm slot
  • Data Output
  • USB port, RS232 communication
  • Nebulizer Type
  • High-efficiency pneumatic/nebulizer
  • Aspiration Rate
  • 2 - 5 mL/min
  • Wavelength Range
  • 190 - 900 nm
  • Readout Units
  • Absorbance, concentration, emission, percent transmission
  • Safety Interlocks
  • Flame sensor, gas pressure sensor, overload protections
  • Lamp Positions
  • 4 (automatic turret or manual switch)
 

ConXport Atomic absorption spectrophotometer Trade Information

  • FOB Port
  • Delhi
  • Payment Terms
  • Letter of Credit (L/C), Paypal, Telegraphic Transfer (T/T)
  • Supply Ability
  • 15 Per Week
  • Delivery Time
  • 6-7 Days
  • Sample Available
  • Yes
  • Sample Policy
  • If order is confirmed we will reimburse the sample cost
  • Main Export Market(s)
  • Asia, Australia, South America, Africa, Central America, Eastern Europe, North America
  • Main Domestic Market
  • All India
  • Certifications
  • ISO,CE,FDA,WHO-GMP
 

ConXport Atomic absorption spectrophotometer About

Product Description Instrument Type - Single Beam ReflectionAchromatic Optics System
Monochromatic- Aberration Corrected Czerny-Turner
Dispersionelements - Grating system 1200 line/mm characterization area 40mm2Scintillation wavelength 250nm
Bandwidth -0.1,0.2,0.4,1nm(4 step auto switching)
WL Range -190-900 NM
WL Accuracy- 0.2NM
WLRepeatability - 0.1 nm max
Resolution- Min 3 lines (279.5 & 279.8 peak and Valley )
HCL housing- Standard 4 lamp turret .( 1 for measurement , 3 in warm-up mode )Option :- 6Lamp / 8 Lamp Turret
Gas control- Automatic control & optimization (flow/pressure)
Safetymeasures - Gas Leak check, prevention of gas release when flame dies out,prevention of flashback through pressure monitoring.
Measurement- Aberration-corrected Czerny-Turner mounting
PhotometricRange - 0-125%, -0.1-3.00A
StaticBaseline Drift - (Cu) +-0.003A/30min
DynamicBaseline Drift t - (Cu) +-0.006A/30min
BackgroundCorrection - High speed self-reversal (BGC-SR) method: High-speed D2 lampmethod (BGC-D2)
CharacteristicConcentration - (Cu) 0.025 g/ml max
Detectionlimit - (Cu) 0.004 g/ml max
Precision -RDS =0.5%
Burner -Air cooled Titanium
Nebulizer -High-efficient Nebulizer
Spraychamber - Anticorrosion material
Safetymeasures - Flame fuel gas, power assisted gas abnormal pressure protection
Test Manner- Flame , flame emission
Concentration- standard curve, standard addition, interpolation
Times ofrepetitive - Measurement 1-30 times, Average Value of A&C Report Printparameters, date result
Dimension& Weight(Flame)700420550 mm; 103 kg(approx.)
Power (Mainunit - with(Flame) - AC 220 V 10%, 50 Hz without sharp fluctuations.
WorkingTemperature range 10-300C
WorkingHumidity range - 40%-85%

 



Precision and Flexibility in Metal Analysis

ConXports Atomic Absorption Spectrophotometer delivers reliable quantitative results through microprocessor-controlled calibration. The adjustable spectral bandwidths and selectable burner heads allow for tailored analysis, accommodating varying sample requirements and atomization conditions. Its intuitive digital display streamlines operation, making complex data accessible and efficiently managed.


Robust Safety and Durability Features

Engineered with built-in safety interlocks including flame and gas pressure sensors, this equipment prioritizes laboratory safety. The titanium/stainless steel burner head and corrosion-resistant metal frame ensure long service life, even at sustained high temperatures. Both automation and manual operation options increase versatility for diverse laboratory environments.

FAQs of ConXport Atomic absorption spectrophotometer:


Q: How does the ConXport Atomic Absorption Spectrophotometer ensure precise metal quantification?

A: The device utilizes microprocessor-controlled calibration, automatic wavelength selection, and adjustable spectral bandwidths, which together provide accurate and repeatable absorbance readings with an error margin of 0.5%.

Q: What safety features are included to protect users during operation?

A: Safety interlocks such as flame sensors, gas pressure monitors, and overload protections are integrated to automatically halt operation in hazardous conditions, ensuring user and equipment protection.

Q: When is this spectrophotometer typically used in laboratories?

A: It is commonly employed during routine quantitative chemical analysis, especially for detecting and measuring metal ions in environmental, industrial, and clinical samples.

Q: Where can the ConXport Atomic Absorption Spectrophotometer be installed?

A: This spectrophotometer can be installed in analytical laboratories, research centers, industrial facilities, and universities where metal quantification is essential.

Q: What is the process for using the spectrophotometer for sample analysis?

A: Users prepare the sample, select appropriate wavelength and flame settings, and introduce the sample via the high-efficiency nebulizer. The device then measures absorbance, emission, or concentration, displaying results on its digital LCD screen.

Q: What are the main benefits of its corrosion-resistant metal construction and borosilicate components?

A: Corrosion-resistant metals and borosilicate glass provide durability, minimize contamination, and allow operation at temperatures up to 1000C, enhancing instrument longevity and measurement reliability.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Spectrophotometer Category

ConXport High-Performance Liquid Chromatography

ConXport High-Performance Liquid Chromatography

Temperature Resistance : Up to 150C

Display Type : LED Display

Features : Auto Calibration, Modular Design, Chemical Resistant

Dimension (L*W*H) : 600 mm x 480 mm x 450 mm

Equipment Materials : Stainless Steel, Glass

Application : Laboratory, Analytical Chemistry

ConXport Advanced Nano Spectrophotometer

ConXport Advanced Nano Spectrophotometer

Temperature Resistance : Up to 40C

Display Type : Digital LCD Display

Features : NanoVolume Sample Analysis, UserFriendly Interface, Integrated Software, USB Connectivity, Data Storage

Dimension (L*W*H) : 200 mm x 150 mm x 130 mm

Equipment Materials : Aluminum Alloy and HighGrade Plastic

Application : MicroVolume Nucleic Acid/Protein Quantification, DNA/RNA Analysis, Laboratory Research

ConXport Peltier Sipper System

ConXport Peltier Sipper System

Temperature Resistance : 10C to +80C

Display Type : LED Digital Display

Features : Compact design, rapid heating/cooling, low noise, high accuracy temperature maintenance, easy to integrate with existing lab setups.

Dimension (L*W*H) : 220 x 120 x 180 mm

Equipment Materials : Stainless steel and highquality polycarbonate

Application : Designed for precise temperature control and sample aspiration in laboratory analysis, particularly for use with spectrophotometers and flow cells.

ConXport  3.  UV-VIS Spectrophotometer Double Beam

ConXport 3. UV-VIS Spectrophotometer Double Beam

Temperature Resistance : Up to 40C operating environment

Display Type : Large Graphical LCD Display

Features : Double beam optics, Wide wavelength range, Builtin printer, Data storage

Dimension (L*W*H) : 500 x 350 x 200 mm

Equipment Materials : Metal body with powder coating

Application : Analytical Laboratory, Research, Chemical Testing



Back to top