08045815886
Change Language
ConXport .  Maddox wing
ConXport .  Maddox wing

ConXport . Maddox wing

ConXport . Maddox wing Specification

  • Measurement Range
  • Used for measuring ocular deviations
  • Model No
  • ConXport Maddox Wing
  • Feature
  • Visual testing of strabismus and phoria; easy-to-clean surface
  • Accuracy
  • Precise alignment for ocular deviation tests
  • Automation Grade
  • Manual Use
  • Core Components
  • Transparent Maddox Rods, Wing-shaped Frame
  • Power Source
  • Manual, No Power Required
  • Equipment Materials
  • High-Quality Transparent Acrylic
  • Type
  • Ophthalmic Diagnostic Tool
  • Usage
  • Strabismus/Maddox Test in Eye Examination
  • Dimension (L*W*H)
  • Approx. 15 cm x 2.5 cm x 0.3 cm
  • Weight
  • Lightweight, approximately 50 grams
  • Light Transmission
  • High optical clarity for accurate results
  • Application
  • Ophthalmology clinical and optometry settings
  • Cleaning
  • Can be cleaned with disinfectant wipes
  • Finish
  • Smooth, polished edges
  • Markings
  • Clearly graduated scales for measurement
  • Reusable
  • Designed for repeated clinical use
  • Patient Safety
  • Non-toxic, skin-safe materials
  • Shape
  • Ergonomic wing form
  • Portability
  • Compact, pocket-sized
 

ConXport . Maddox wing Trade Information

  • FOB Port
  • Delhi
  • Payment Terms
  • Letter of Credit (L/C), Telegraphic Transfer (T/T), Paypal
  • Supply Ability
  • 15 Per Week
  • Delivery Time
  • 6-7 Days
  • Sample Available
  • Yes
  • Sample Policy
  • If order is confirmed we will reimburse the sample cost
  • Main Export Market(s)
  • Australia, South America, Eastern Europe, Western Europe, Middle East, Central America, Asia, North America, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO,CE,FDA,WHO-GMP
 

About ConXport . Maddox wing

Maddox Wing

A convenient hand-held,quick and efficient near test for heterophoria.

Esophoria and exophoriaare measured by the horizontal scale. Hyperphoria is measured on the redvertical scale. Cyclophoria may be assessed by moving the red arrow pointerparallel to the horizontal scale. Each eye piece has cell spaces to accommodatethe patients near prescription if required.

 



Accurate Ocular Assessments

With its high optical clarity and precisely graduated scales, the ConXport Maddox Wing supports ophthalmologists and optometrists in conducting accurate and reliable strabismus and phoria tests. This accuracy is fundamental in diagnosing and managing ocular deviations effectively.


Designed for Workflow Efficiency

Compact and lightweight, this diagnostic wing can be carried anywhere and easily fits into a pocket. Its easy-to-clean, smooth surface and robust acrylic material support rigorous, repeated use in busy clinical settings without compromising hygiene or patient safety.

FAQs of ConXport . Maddox wing:


Q: How is the ConXport Maddox Wing used during an eye examination?

A: The device is used to perform Maddox and strabismus tests by aligning its graduated scales with the patients eyes. The patient views through the transparent Maddox rods, which help highlight ocular deviations, aiding in precise measurement and diagnosis.

Q: What makes the ConXport Maddox Wing ideal for ophthalmology clinics?

A: Its high optical clarity, accurate measurement scales, and ergonomic design enable comfortable and accurate examinations. Being lightweight, portable, and made from non-toxic, skin-safe acrylic, it ensures ease of use and patient safety in a clinical environment.

Q: When should the Maddox Wing be used in practice?

A: It is primarily utilized during ocular deviation assessments, such as Maddox or strabismus tests, to objectively measure phorias and tropias during routine or specialized eye examinations.

Q: Where is the best environment to use the ConXport Maddox Wing?

A: It is best suited for ophthalmology clinics, optometry practices, and clinical settings where regular eye examinations and strabismus evaluations are conducted.

Q: What is the process for cleaning and maintaining the Maddox Wing?

A: Simply wipe the wing with disinfectant wipes after each use. Its smooth, polished acrylic surface is resistant to chemical damage, ensuring long-term use and easy maintenance.

Q: What are the benefits of the ergonomic wing-shaped design?

A: The ergonomic design ensures a comfortable grip for the examiner and a stable fit during patient assessment, reducing handling errors and improving the accuracy of test results.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in ENT And Ophthalmic Instruments Category

ConXport Surgeon Stool Normal Quality

ConXport Surgeon Stool Normal Quality

Feature : Height adjustable, Smooth movement

Weight : Approx. 8 kg

Model No : ConXport Surgeon Stool Normal Quality

Automation Grade : Manual

Equipment Materials : Mild steel frame, Stainless steel seat

Type : Surgeon Stool, Normal Quality

ConXport Capsulorhexis Forcep

ConXport Capsulorhexis Forcep

Feature : Spring action, fine atraumatic tips, ergonomic design for precision handling

Weight : Approx. 15 g

Model No : CONX012

Automation Grade : Manual

Equipment Materials : Medical Grade Stainless Steel

Type : Surgical Forcep

ConXport .  Vannas Scissor Angled Upward

ConXport . Vannas Scissor Angled Upward

Feature : Fine sharp tips, lightweight, anticorrosive

Weight : Approx. 1015 grams

Model No : CXPVS110

Automation Grade : Manual

Equipment Materials : Highgrade stainless steel

Type : Vannas Scissor Angled Upward

ConXport Vannas Capsulotomy Scissor Angled Upward

ConXport Vannas Capsulotomy Scissor Angled Upward

Feature : Angled upward for precise capsulotomy; ultrafine tips; ergonomic handle

Weight : Approx. 1030 grams

Model No : ConXport Vannas Capsulotomy Scissor Angled Upward

Automation Grade : Manual

Equipment Materials : Highgrade stainless steel

Type : Capsulotomy Scissor, Surgical Instrument



Back to top