08045815886
Change Language
ConXport Quadruple Leukocyte Reduction Filter
ConXport Quadruple Leukocyte Reduction Filter

ConXport Quadruple Leukocyte Reduction Filter

ConXport Quadruple Leukocyte Reduction Filter Specification

  • Temperature Range
  • Storage: 4°C to 30°C
  • Automation Grade
  • Manual
  • Treatment Type
  • Blood Filtration
  • Accuracy
  • Leukocyte Reduction >99% (to <1x10^6/unit)
  • Application
  • Blood Component Separation
  • Use
  • Removal of Leukocytes from Blood Units
  • Storage Capacity
  • Single Filter (for one Quadruple Bag)
  • Properties
  • Sterile, Non-pyrogenic, Single-use
  • Weight
  • Approx. 85 grams
  • Shape
  • Rectangular
  • Humidity Range
  • Up to 90% RH, non-condensing
  • Color Code
  • Transparent White
  • Function
  • Leukocyte Filtration
  • Dimension (L*W*H)
  • 220 mm x 105 mm x 35 mm (approx)
  • Product Type
  • Quadruple Leukocyte Reduction Filter
  • Suitable For
  • Quadruple Blood Bag Systems
  • Height
  • 35 mm
  • Material
  • Medical Grade Polycarbonate and Polyester Fiber
  • Pore Size
  • Optimized for effective leukocyte retention
  • Shelf Life
  • 36 months
  • Filtration Efficiency
  • >99.99%
  • Blood Bag Compatibility
  • Compatible with standard quadruple blood bag systems
  • Disposability
  • Single Use
  • Compliance Standard
  • CE Marked / ISO Certified
  • Flow Rate
  • 50-150 ml/minute
  • Sterilization
  • Radiation Sterilized
  • Latex Free
  • Yes
 

ConXport Quadruple Leukocyte Reduction Filter Trade Information

  • FOB Port
  • Delhi
  • Payment Terms
  • Letter of Credit (L/C), Telegraphic Transfer (T/T), Paypal
  • Supply Ability
  • 15 Per Week
  • Delivery Time
  • 6-7 Days
  • Sample Available
  • Yes
  • Sample Policy
  • If order is confirmed we will reimburse the sample cost
  • Main Export Market(s)
  • Western Europe, Australia, North America, Eastern Europe, Central America, Middle East, South America, Asia, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO,CE,FDA
 

About ConXport Quadruple Leukocyte Reduction Filter

For Whole BloodCollection And Separation Of 4 Different Blood Components - Red Blood Cells,Plasma, Leukocytes And Platelets, Obtained Through The Process OfCentrifugation And Extraction.

The Primary BagContains Cpd Anticoagulant Solution And One Satellite Bag Contains Sag-MAdditive Solution For Red Blood Cell Preservation. One Satellite Bag Is For5-Day Platelet Storage.

Imported Film

Ultra SharpNeedle

OptionalFeatures

Pre-DonationSampling Device, Anti-Needle-Stick Device



Exceptional Leukocyte Filtration Efficiency

The ConXport Quadruple Leukocyte Reduction Filter achieves over 99.99% leukocyte removal, ensuring the highest safety standards for blood component separation. Its carefully optimized pore size and medical-grade material construction offer precise and reliable performance, essential for transfusion-critical environments.


Universal Compatibility and Ease of Use

Designed for compatibility with standard quadruple blood bag systems, this filter is both practical and versatile. Its manual operation makes integration simple within existing workflows for blood banks, manufacturers, and healthcare providers who require fast and dependable leukocyte reduction.


Sterile, Disposable, and Certified Safe

Each filter is radiation sterilized, latex-free, and intended for single use, minimizing contamination risks while guaranteeing user and patient safety. CE Marked and ISO Certified, it assures compliance with international quality regulations and instills confidence in every use.

FAQs of ConXport Quadruple Leukocyte Reduction Filter:


Q: How does the ConXport Quadruple Leukocyte Reduction Filter work?

A: This filter utilizes an optimized pore structure and medical-grade polyester fibers to physically remove leukocytes from blood units as the blood flows through at 50-150 ml/minute. The process achieves more than 99.99% leukocyte reduction, rendering the blood suitable for safe transfusion.

Q: What is the primary benefit of using this leukocyte reduction filter?

A: The main advantage lies in its exceptionally high leukocyte removal efficiency (>99.99%), which helps to significantly lower the risk of leukocyte-mediated transfusion reactions and improves overall blood safety for recipients.

Q: When should this filter be used in blood component separation?

A: Use the filter during processing of whole blood units within standard quadruple blood bag systems, specifically prior to storage or transfusion, to ensure optimal leukocyte reduction and enhance transfusion outcomes.

Q: Where can the ConXport filter be used?

A: The filter is ideal for hospital blood banks, blood component manufacturers, and healthcare centers across India and internationally, wherever sterile, safe blood processing is necessary.

Q: What is the shelf life and storage condition requirement?

A: The filter has a shelf life of 36 months. Store it at temperatures between 4C and 30C and up to 90% relative humidity (non-condensing) to preserve sterility and integrity before use.

Q: Is the filter compatible with all blood bag systems?

A: It is specifically designed for and compatible with standard quadruple blood bag systems, making it widely adoptable where such systems are in operation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Blood Bank Equipments Category

ConXport BLOOD BANK REFRIGERATED CENTRIFUGE

ConXport BLOOD BANK REFRIGERATED CENTRIFUGE

Properties : Digital Control, Overtemperature Protection

Treatment Type : Blood Component Processing

Shape : Rectangular

Weight : Approx. 100 kg

Application : Blood Component Separation

Use : Centrifugation of Blood and Blood Components

ConXport Blood Donor Couch 2 Functions Electric

ConXport Blood Donor Couch 2 Functions Electric

Properties : Ergonomically designed, Comfortable armrests, Adjustable positions

Treatment Type : Blood Donation

Shape : Rectangular with Contoured Edges

Weight : Approx. 60 kg

Application : Blood Donation in Hospitals and Blood Banks

Use : Used to comfortably position blood donors during blood collection

ConXport Blood Donor Couch 3 Functions Electric

ConXport Blood Donor Couch 3 Functions Electric

Properties : Electric height, leg and backrest adjustment, washable surface, high comfort PU cushion, smooth operation

Treatment Type : Blood Donation

Shape : Reclining Couch

Weight : Approx. 7090 kg

Application : Blood Banks, Hospitals, Clinics

Use : For safe and comfortable blood donation

ConXport Blood Bag Quadruple Cod / Sag

ConXport Blood Bag Quadruple Cod / Sag

Properties : Pyrogen Free, NonToxic, Leak Proof

Treatment Type : Blood Collection

Shape : Rectangular

Weight : Approx 120160g per set

Application : Blood Storage, Collection, Separation

Use : Blood Collection and Component Separation



Back to top