About ConXport Ventilator Portable
Displaymode : High-definition 5.7 LCD screen display
Ventilationmode : IPPV, SIPPV, SIMV, MANUAL
Ventilation function : PEEP,SIGH, IRV
Ventilationparameters :
Tidalvolume 50~1500ml
Rate 2~99bpm
SIMVRate 2~20bpm
I:E 2:1~1:8
Inspiratorytrigger pressure -1.0~2.0 kPa
PEEP 0~2.0 kPa
Pressurerange 1.0~6.0 kPa
SIGH 1.5 times the inspiratory time
Parametersfor ventilation monitoring tidal volume, minute ventilation volume, IPPVrate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure- time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure
SecurityAlarm System
Airwaypressure alarm upper limit setting range 1.0~6.0 kPa
low limit setting range 0.4~2.0 kPa
Per-minuteventilation volume alarm upper limit setting range 3.0~30L/min
low limit setting range 1.0~10L/min
Sustainedhigh-pressure alarm : It will give alarm when stress have consistently beenhigher than 2.5 kPa
Suffocationalarm :
Itwill give sound and light alarm if there is no tidal volume input for 15seconds
Poweralarm
PowerAC 220V10% 50Hz1Hz UPS, Storage battery
Versatile Ventilation for Critical CareThe ConXport Ventilator Portable accommodates a broad spectrum of clinical scenarios with its multiple modes, including Assist-Control, SIMV, and CPAP. It delivers effective intermittent positive pressure ventilation and synchronized mandatory support, making it suitable for both adults and pediatrics during emergency and transport.
Designed for Portability and Ease of UseWith a compact design weighing approximately 4.3 kg and built-in rechargeable battery offering up to three hours of operation, this ventilator is easy to transport and deploy. The LCD control panel with touch button controls, along with comprehensive alarms, ensures straightforward operation for rapid response in critical situations.
Reliable Performance in Various SettingsEngineered to function within a wide temperature and humidity range, the ventilator maintains consistent accuracy (2 cm H2O) whether in ambulances, hospital wards, or field setups. Its durable ABS plastic and metal housing ensures reliability and longevity, even in challenging environments.
FAQs of ConXport Ventilator Portable:
Q: How do I operate the ConXport Ventilator Portable during emergency or transport situations?
A: Simply power on the device using the AC mains or internal battery, and use the touch buttons on the LCD panel to select the desired ventilation mode (Assist-Control, SIMV, or CPAP), set the tidal volume (801200 ml), and adjust other parameters. This enables rapid and tailored respiratory support for patients in ambulances or field settings.
Q: What safety systems are integrated into the ventilator?
A: The ventilator has advanced alarm systems that monitor for high pressure, low pressure, apnea, and power failure. These alarms, along with a clear digital display, alert users to any issues, allowing for immediate response and ensuring patient safety.
Q: When should I use the built-in battery backup?
A: The built-in rechargeable battery provides up to three hours of operation, ideal for situations where AC power is unavailable, such as patient transport or during power outages, ensuring continuous ventilation support.
Q: Where can this ventilator be used effectively?
A: Its design supports use in ambulances, hospital settings, and field medical setups. Lightweight and portable construction, along with a wide voltage range (110240 V AC), enables operation in diverse environments domestically and internationally.
Q: What is the process for setting oxygen concentration on this ventilator?
A: Use the adjustable controls on the LCD panel to set the desired oxygen concentration, anywhere between 21% and 100%, depending on the patients respiratory needs and clinical protocol.
Q: What benefits does this device offer for medical teams during emergencies?
A: Medical teams benefit from its quick setup, flexible ventilation modes, reliable alarm systems, and portability. The ventilators ease of use and comprehensive features allow for effective support of critically ill patients in time-sensitive scenarios.