08045815886
Change Language
Digital Photo Fluorometer
Digital Photo Fluorometer

Digital Photo Fluorometer

Digital Photo Fluorometer Specification

  • Accuracy
  • 2% FSD
  • Features
  • High sensitivity, digital readout, compact design, long lamp life, pre-focused light source, easy calibration, direct concentration display
  • Display Type
  • Digital LED display
  • Power Supply
  • Mains, 220-240V AC
  • Control Type
  • Digital
  • Temperature Resistance
  • Ambient to 40C
  • Glass Type
  • Quartz Cuvette
  • Shape
  • Rectangular
  • Type
  • Digital Photo Fluorometer
  • Dimension (L*W*H)
  • 285 x 230 x 105 mm
  • Equipment Type
  • Fluorometer
  • Equipment Materials
  • Metal body with corrosion resistant finish
  • Power
  • 10 W
  • Voltage
  • 220 V AC, 50 Hz
  • Material
  • Stainless steel and powder coated mild steel
  • Application
  • For quantitative analysis of concentration of solutions and determination of nucleic acids or proteins
 
 

About Digital Photo Fluorometer

We are certified organization engaged in manufacturing and exporting a wide range of Digital Photo Fluorometer. These meters are manufactured by our well experienced personnel team using the best quality materials procured from the authentic vendors. The meter is checked on performance and efficiency parameters by the quality inspectors before making available to the clients at reasonable price. We can customize our Digital Photo Fluorometer as per the requirements of our clients.

Digital Photo Flurometer measures fluorophors like vitamins, quinine and metals. Supplied with 2 primary and 3 secondary filters mounted on holders. Results are displayed on 3 digit 7 segment LED. Sensitivity in 4 ranges. Highly accurate & stable.

Product Details

Minimum Order Quantity

1 Number

Model

ARGLabs-330

Application

Industrial Use, Laboratory Use

Brand

ARG Labs

Display

Digital

Display

262x340x165 mm (Approx.)

Test Tube

A set of 5.



Compact, Durable, and Easy to Use

Engineered with a robust metal body and corrosion-resistant finish, this digital photo fluorometer is designed for both durability and portability. Its compact dimensions (285 x 230 x 105 mm) and net weight of approximately 6 kg suit any laboratory environment, while the digital display and streamlined controls enable seamless operation even for beginners.


High Sensitivity and Quick Response

With a high-intensity LED and photodiode-based detection, the fluorometer achieves exceptional sensitivity (10^-7 g/ml of quinine sulphate) and provides results in less than 3 seconds. Automatic calibration and direct concentration readout ensure reliable and reproducible results for both research and clinical analysis.


Versatile Applications in Analytical Science

The instrument is tailored for the quantitative analysis of solutions, enabling precise determination of nucleic acids and proteins. Used in research, clinical, and educational laboratories, it simplifies complex fluorescence measurements, making it a valuable analytical tool across many scientific disciplines.

FAQs of Digital Photo Fluorometer:


Q: How do I operate the Digital Photo Fluorometer for a fluorescence measurement?

A: Simply place your prepared sample in the supplied 1 cm path length quartz cuvette and insert it into the sample holder. Switch on the instrument, and it will automatically calibrate using the standard sample. Select measurement mode, and within 3 seconds, you will receive a direct fluorescent intensity reading on the digital LED display.

Q: What types of samples can be analyzed with this fluorometer?

A: This instrument is specifically designed for quantitative analysis of nucleic acid or protein solutions. It is also suitable for detecting other fluorescent analytes within the wavelength range of 365 nm excitation, provided the sample is compatible with quartz cuvettes and ambient laboratory conditions.

Q: When should I calibrate the fluorometer?

A: This fluorometer features automatic calibration, which runs each time you power on the device and insert the standard sample. Regular calibration ensures ongoing accuracy, especially when conducting multiple measurements or after extended use.

Q: Where should I place the fluorometer for optimal operation?

A: Install the fluorometer in a laboratory environment that is well-ventilated and free from excessive humidity (less than 85% RH, non-condensing). The instrument is built with corrosion-resistant materials, but proper placement on a stable, flat surface is recommended for best results.

Q: What is the process of analyzing nucleic acids or proteins using this device?

A: Prepare your sample according to standard laboratory protocols. Add it to the quartz cuvette, and after automatic calibration, place it in the cuvette holder. The fluorometer will excite the sample at 365 nm and measure the emitted fluorescence, providing a digital readout of concentration.

Q: What benefits does this fluorometer offer over other analytical instruments?

A: It combines high sensitivity, fast response, and direct digital readout in a compact, durable design. The pre-focused LED light source and automatic calibration minimize user intervention, making it reliable for routine laboratory use and reducing the chance of errors.

Q: How does the digital display enhance usability?

A: The bright digital LED display provides clear, immediate readings of fluorescent intensity or concentration, making the results easy to interpret and reducing the possibility of misreading data during analyses.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Photo Colorimeters Category

ConXport  Microprocessor Flame Photometer

ConXport Microprocessor Flame Photometer

Accuracy : Better than 2% (for Na/K Standards)

Power : 230V AC, 50 Hz

Features : Auto Ignition, Auto Cutoff, Direct Concentration Display, Curve Fitting, Air Compressor Builtin, Inbuilt Calibration Storage

Material : Stainless Steel Burner, HighQuality Optical Filters

Display Type : 4digit LED Digital Display

Application : Measurement of Sodium, Potassium, Calcium, Lithium in aqueous solutions

ConXport  Digital Flame Photometers

ConXport Digital Flame Photometers

Accuracy : 2% for Na & K

Power : 230 V AC, 50 Hz

Features : Dual Channel Output, Automatic Ignition, Calibrated for Na & K, Expandable for Ca and Li, Stable flame, Easy operation and maintenance

Material : ABS plastic and metal

Display Type : Digital LED Display

Application : Laboratory, clinical and educational analysis of sodium, potassium, calcium, and lithium

PH Meter Microprocessor

PH Meter Microprocessor

Accuracy : 0.01 pH

Power : Low power consumption

Features : Automatic calibration temperature compensation

Material : Durable plastic and electronic components

Display Type : Digital

Application : Laboratory and industrial pH measurement



Back to top