Autoclave Pressure Cooker Specification

  • Type
  • Rectangular, Horizontal
  • Chamber Size
  • 800 x 400 x 300 mm
  • Chamber Thickness
  • 4 mm
  • Outer Size
  • 1070 x 600 x 600 mm
  • Compressed Air
  • 0.5-0.6 Mpa
  • Door Type
  • Vertical Sliding Door
  • Design Pressure
  • 0.25 Mpa
  • Working Pressure
  • 0.22 Mpa
  • Design Temperature
  • 134C
  • Heat Uniform
  • 1C
  • Insulation
  • Rock Wool
  • Net Weight
  • 260 Kg
  • Recording Parameters
  • Digital Chart Recorder
  • Spraying Mode
  • Top & Side Spraying
  • Outer Trolley
  • Stainless Steel, Removable
  • Inner Trolley
  • Stainless Steel, with Perforation
  • Spraying Piping
  • 316L Stainless Steel
  • Steam
  • Saturated Steam (from External Generator)
  • Sterilizing Temperature
  • 121C
  • Working Temperature
  • 121C
  • Sterilization Time
  • 30-60 minutes adjustable
  • Temperature Scope
  • 100C 134C
  • Piping System
  • Integrated for Steam and Water
  • Valves
  • Automatic Control Valves
  • Power Consumption
  • 6 kW
  • Voltage
  • 220V / 50Hz
  • Cycle Programs
  • Pre-set & Custom Programs
  • Material of Construction
  • 316L Stainless Steel Chamber
  • Standards Compliance
  • ISO & CE Certified
  • Control System
  • PLC Based with Touch Screen
  • Water Consumption per Cycle
  • 25 L
  • Safety Features
  • Pressure Relief Valve, Over-Temperature Cutoff
  • Usage
  • Medical, Laboratory, Pharmaceutical
  • Timer
  • Programmable
  • Pre-heating Mode
  • Available
  • Cooling System
  • Integrated Air Cooling
  • Display
  • LED Digital
  • Door Seal Type
  • Silicon Gasket
  • Interior Finish
  • Polished Mirror Finish
 

Autoclave Pressure Cooker Trade Information

  • FOB Port
  • Delhi
  • Payment Terms
  • Paypal, Letter of Credit (L/C), Telegraphic Transfer (T/T)
  • Supply Ability
  • 15 Per Week
  • Delivery Time
  • 7 Days
  • Sample Available
  • Yes
  • Sample Policy
  • If order is confirmed we will reimburse the sample cost
  • Main Export Market(s)
  • Australia, North America, South America, Eastern Europe, Western Europe, Middle East, Africa, Central America, Asia
  • Main Domestic Market
  • All India
  • Certifications
  • ISO, CE, FDA, WHO-GMP
 

About Autoclave Pressure Cooker

Autoclave Wing Nut is also known as Wing Nut  Sterilizers, Portable Wing Nut Autoclaves Sterilizers

Autoclave Wing Nut is a part of Steam Sterilizing Equipment

Autoclave Wing Nut is Electrical and is made of Stainless Steel

The body and lid has Seamless Construction from Extra Thick Stainless Steel Sheet Body & Lid for more safety and life long performance.

The Anti-Bulging & Fuel Saver Base is provided for Additional Strength, Fuel Saving and Time Saving.

The depression at centre of the lid helps in Additional Strength.

The Gasket is ISI Marked food grade synthetic rubber gasket for better reliability, hygiene & longer life.

The Gasket Release System (GRS) & fusible plug type safety valve is available for Triple-Safety.

The pressure gauge is Colour-coded Pressure Gauge to indicate the safe and danger zones.

The repeating type safety valve is provided for better Safety and longer &error-free performance.

The vacuum release & steam release valves are made of Stainless Steel for longer life and to avoid toxic deposits on valves due to oxidation.

The heating element is ISI Marked which is made of thick and heavy copper pipe with very thick chrome plating.

The Electric Cable has heavy electric wires to comfortably bear the heating load.

The3 Pin Plug & Element Connector is of High quality for electrical safety.

The handles is made from heat resistant, impact tolerant, finest quality bakelite, fitted with Stainless Steel screws to avoid easy loosening of handles.

The inside tripod stand is made of Stainless Steel with extra height to avoid wetting of instruments.

The outer stand is well designed to provide proper stability to the Autoclave Wing Nut.

 



Efficient Sterilization for Diverse Applications

Designed for rigorous medical, laboratory, and pharmaceutical sterilization, the autoclave pressure cooker utilizes saturated steam from an external generator and sustains precise temperatures between 100C and 134C. With customizable cycle programs, adjustable timers, and uniform heat distribution, this equipment is tailored to deliver consistent performance across a variety of sterilization needs.


Robust Safety and Control Features

Safety is paramount, with features including a silicon gasket door seal, pressure relief valve, and over-temperature cutoff. The integrated PLC-based touch screen streamlines operation, while digital chart recording ensures accurate documentation of sterilization parameters for compliance and traceability.


Superior Construction and User Convenience

Built from high-grade 316L stainless steel, both the chamber and spraying piping are exceptionally durable and corrosion resistant. The vertical sliding door and removable stainless steel trolley provide convenient access and easy transport of items, while the air cooling system accelerates post-cycle handling and enhances workflow productivity.

FAQs of Autoclave Pressure Cooker:


Q: How does the autoclave pressure cooker ensure safe operation during the sterilization process?

A: The autoclave is equipped with multiple safety features, including a pressure relief valve to prevent excess pressure buildup and an over-temperature cutoff that automatically halts operation if unsafe temperatures are detected. The robust silicon gasket provides a secure seal, minimizing the risk of leaks.

Q: What materials are used in the construction of the autoclave, and how do these benefit users?

A: The chamber and spraying piping are constructed from 316L stainless steel, which is resistant to corrosion and chemical damage. The mirror-polished interior ensures thorough cleaning and prevents contamination, making it ideal for strict medical, laboratory, and pharmaceutical environments.

Q: When should users select pre-set versus custom sterilization programs on the autoclave?

A: Pre-set cycles are suitable for standard sterilization tasks, providing reliable, repeatable results for commonly used protocols. Custom programs, available via the PLC touch screen, allow users to tailor cycle parameters (such as temperature and duration) for unique equipment or materials requiring specific conditions.

Q: Where is this autoclave typically installed, and what infrastructure is required?

A: Commonly deployed in hospitals, research labs, and pharmaceutical manufacturing facilities, the autoclave requires access to an external steam generator, a compressed air source (0.50.6 Mpa), and a standard electrical connection (220V / 50Hz). It is designed for easy installation with integrated piping for steam and water.

Q: How does the integrated cooling system improve the process and user safety?

A: The autoclaves air cooling system accelerates the reduction of chamber temperature after sterilization, permitting faster handling and reducing the risk of burns or heat-related accidents. This feature also helps maintain sterility by preventing premature exposure to contaminants.

Q: What benefits does the programmable timer and digital chart recorder provide to users?

A: A programmable timer allows precise control over sterilization duration, optimizing cycles for different items. The digital chart recorder automatically logs temperature, pressure, and cycle parameters, supporting compliance with ISO and CE standards and enabling verification for audit or quality assurance purposes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Autoclave Category

Vertical Autoclave Double Wall

Vertical Autoclave Double Wall

Design Pressure : 2.5 bar

Compressed Air : 68 bar (for door and seal operation)

Piping System : CIP integrated piping, safety systems

Temperature Scope : Ambient to 134C

Door Type : Radial Locking, Manual/Automatic

Outer Size : 550mm x 750mm

Automatic Horizontal Steam Sterilizer

Automatic Horizontal Steam Sterilizer

Design Pressure : 2.5 kg/cm

Compressed Air : 57 kg/cm

Piping System : SS 304 seamless pipe

Temperature Scope : Up to 134C

Door Type : Automatic horizontal sliding door

Outer Size : 1460 x 690 x 900 mm

Vertical Autoclave Single Wall Fully Automatic

Vertical Autoclave Single Wall Fully Automatic

Design Pressure : 2.2 Bar

Compressed Air : 68 Bar

Piping System : 304/316 grade stainless steel

Temperature Scope : Room Temp to 134C

Door Type : Radial Locking / Automatic Door

Outer Size : 650 x 650 x 1200 mm (approx)

Electric Autoclave Cooker Type

Electric Autoclave Cooker Type

Design Pressure : 2.1 bar

Compressed Air : 0.60.8 MPa

Piping System : Automatic Control

Temperature Scope : Room Temperature 134C

Door Type : Radial Locking Type

Outer Size : 950 x 600 x 470 mm



Back to top