About Conxport Digital Photo Fluorometer
Conxport Digital Photo Fluorometer
Digital Photo Fluorometer measures fluorophores like vitamins, quinine and metals. Supplied with 2 primary and 3 secondary filters mounted on holders. Results are displayed on 3 digit 7 segment LED. Sensitivity in 4 ranges. Highly accurate & stable.
FEATURES:
| Minimum Order Quantity | 1 Number |
| Model | ARGLabs-330 |
| Application | Industrial Use, Laboratory Use |
| Brand | ARG Labs |
| Display | Digital |
| Display | 262x340x165 mm (Approx.) |
| Test Tube | A set of 5. |
High Sensitivity and Stable PerformanceEngineered with a high grade photo diode sensor and quartz cuvette holder, the Digital Photo Fluorometer guarantees sensitive, accurate fluorescence measurement. Its digital display and controls allow for easy operation, resulting in reliable data for laboratory research and analysis.
Robust and Compact DesignHoused in aluminum with powder coating, this instrument is built for durability in demanding lab settings. Its compact size (220 x 170 x 95 mm) and manageable weight (approx. 2.5 kg) make it easy to integrate into busy laboratories without occupying unnecessary space.
User-Friendly Calibration and OperationManual calibration using standard samples provides flexibility and precision in measurement. The intuitive digital readout and control interface streamline daily operation, making the fluorometer ideal for routine as well as advanced analytical tasks.
FAQs of Conxport Digital Photo Fluorometer:
Q: How do I calibrate the Conxport Digital Photo Fluorometer?
A: Calibration is performed manually using standard fluorescence samples. Follow the instructions provided in the user manual to adjust the instrument for accurate readings before sample analysis.
Q: What types of samples can I analyze with this fluorometer?
A: This instrument is designed for quantitative analysis of fluorescence in various laboratory solutions using a 1 cm path length quartz cuvette, suitable for routine and research applications.
Q: When is it necessary to replace the UV lamp?
A: The high intensity UV lamp has an estimated service life of approximately 1000 hours. Replace the lamp once performance decreases or the operational hours are reached to maintain sensitivity.
Q: Where can the Digital Photo Fluorometer be used?
A: The fluorometer is suitable for laboratories conducting photofluorometric analysis, including academic, research, clinical, and industrial environments, provided the operating temperature is maintained between 10C and 40C.
Q: What is the process for analyzing a sample using this instrument?
A: Prepare your solution in a quartz cuvette, insert it into the sample holder, calibrate the instrument as needed, and use the digital control panel to initiate measurement for fluorescence quantification.
Q: What benefits does the Conxport Digital Photo Fluorometer offer?
A: It provides high sensitivity, stable digital readings, easy calibration, and compact design, making it an efficient solution for precise fluorescence analysis in laboratory settings.