08045815886
Change Language
ConXport Edta K2 Tube Vacuum
ConXport Edta K2 Tube Vacuum

ConXport Edta K2 Tube Vacuum

ConXport Edta K2 Tube Vacuum Specification

  • Features
  • Pre-filled with EDTA K2 anticoagulant, Leak-proof cap, Color code: Purple
  • Shape
  • Cylindrical
  • Accuracy
  • Precise Volume Fill Mark
  • Temperature Resistance
  • Stable at 4C to 25C
  • Type
  • Vacuum Blood Collection Tube
  • Dimension (L*W*H)
  • 13 x 75 mm
  • Equipment Type
  • Vacuum Tube
  • Equipment Materials
  • Plastic (Polyethylene Terephthalate)
  • Material
  • PET
  • Application
  • Blood Sample Collection for Hematology
  • Capacity (Ltr)
  • 2 ml
  • Cap Color
  • Purple
  • Use
  • Single Use
  • Shelf Life
  • 18 Months
  • Draw Volume
  • 2 ml
  • Anticoagulant
  • EDTA K2 (Ethylenediaminetetraacetic Acid, Potassium Salt)
  • Packaging
  • 100 Tubes per Pack
  • End Use
  • Clinical Laboratory, Hospital & Diagnostic Center
  • Sterility
  • Sterile, Pyrogen-Free
  • Tube Closure Type
  • Rubber Stopper
 

ConXport Edta K2 Tube Vacuum Trade Information

  • FOB Port
  • Delhi
  • Payment Terms
  • Letter of Credit (L/C), Paypal, Telegraphic Transfer (T/T)
  • Supply Ability
  • 21 Per Week
  • Delivery Time
  • 6-7 Days
  • Sample Available
  • Yes
  • Sample Policy
  • If order is confirmed we will reimburse the sample cost
  • Main Export Market(s)
  • Western Europe, Asia, Australia, North America, Eastern Europe, Middle East, Central America, South America, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO,CE,FDA
 

About ConXport Edta K2 Tube Vacuum

EDTA K2 Tubes CanEffectively Chelat The Calcium Ion Of Blood Which Can Prevent The BloodCoagulation.

EDTA K2 Tube DoesNot Affect The Count And Size Of The Leukocyte And Keep Erythrocyle Invariable.

Cap Colour : LavenderOr Purple

Max. VacuumDegree Tolerance : +10 %

Invert The Tube For6-8 Times Immediately After Drawing Blood.

EDTA K2 Tube IsUsed In Clinical Hematology Test & Blood Banking



Optimized Blood Sample Preservation

The EDTA K2 Vacuum Tube is pre-filled with an effective anticoagulant (EDTA K2) to prevent clotting, ensuring that blood samples remain viable for hematology testing. Its robust design and secure closure minimize the risk of contamination or leakage during transportation and storage.


Precise and Reliable Collection

Designed for a consistent draw volume of 2 ml, the tube features clear fill marks for accuracy. The vacuum technology facilitates effortless blood collection, supporting reliable results across hospitals, diagnostic centers, and clinical laboratories.


Convenient and Safe for Use

With its single-use, sterile construction, the ConXport EDTA K2 Tube promotes patient and staff safety. The leak-proof, purple rubber stopper ensures secure handling, while the sturdy PET material offers excellent temperature stability and impact resistance.

FAQs of ConXport Edta K2 Tube Vacuum:


Q: How do I use the ConXport EDTA K2 Tube Vacuum for blood collection?

A: Simply attach the tube to a compatible holder and needle system, insert the needle into the vein, and allow the vacuum to draw exactly 2 ml of blood. Gently invert the tube several times to mix the EDTA K2 anticoagulant with the specimen.

Q: What is the primary benefit of using EDTA K2 in this tube?

A: EDTA K2 acts as an effective anticoagulant, preventing blood from clotting. This ensures the integrity of blood samples, which is critical for accurate hematology testing.

Q: Where can the ConXport EDTA K2 Tube Vacuum be used?

A: This vacuum tube is suitable for clinical laboratories, hospitals, and diagnostic centers that require reliable blood sample collection for hematology analysis.

Q: When should the collected sample be processed after using the tube?

A: It is recommended to process hematology samples as soon as possible after collection to ensure optimal test accuracy and prevent any changes in the specimens properties.

Q: What materials are used to manufacture the tube and how does this benefit the user?

A: The tube is made from robust PET (Polyethylene Terephthalate), providing durability, impact resistance, and chemical inertness, which help protect sample integrity during handling and storage.

Q: Is the ConXport EDTA K2 Tube designed for single use, and why is this important?

A: Yes, each tube is intended for single use only. Single-use design minimizes the risk of cross-contamination and enhances patient and operator safety.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Pathology Laboratory Equipment Category

ConXport Esr Stand Plastic 6 Tubes

ConXport Esr Stand Plastic 6 Tubes

Application : Laboratory ESR Testing

Shape : Rectangular

Material : Durable Plastic

Control Type : Manual

Type : Other, ESR Stand

Equipment Materials : Plastic

ConXport 2 Key Differential Counter

ConXport 2 Key Differential Counter

Application : Used for blood cell counting in Hematology laboratories

Shape : Rectangular

Material : ABS Plastic Body

Control Type : Manual

Type : Other, Manual Differential Counter

Equipment Materials : Plastic and Metal

ConXport Clot Activator Tube Non Vacuum

ConXport Clot Activator Tube Non Vacuum

Application : Blood Collection and Serum Separation

Shape : Cylindrical

Material : Medical Grade Plastic/Glass

Control Type : Manual

Type : Other, Clot Activator Tube (Non Vacuum)

Equipment Materials : Glass/Plastic

ConXport Esr Tubes Glass Marienfeld

ConXport Esr Tubes Glass Marienfeld

Application : Erythrocyte Sedimentation Rate (ESR) determination in hematology

Shape : Cylindrical

Material : Borosilicate Glass

Control Type : Manual

Type : Other, ESR Tube

Equipment Materials : Glass



Back to top